StressXpress®
Cyclic GMP EIA Kit (Discontinued)

Quantitative colorimetric detection of cGMP

Catalog No. SKT-211

0 out of 5 based on 0 customer ratings
Species Reactivity ALL
Sample Types Cell lysates, EDTA Plasma, Saliva, Tissue, Tissue Culture Media, Urine
SKU: SKT-211 Categories: ,

Clear
SKT-211_Cyclic_GMP_EIA_Kit_Regular_Format_Standard_Curve_Fig2.png
Graph of the Acetylated Format Typical Standard Curve for the Cyclic GMP EIA Kit StressXpress - SKT-211Graph of the Linearity Recovery for the Cyclic GMP EIA Kit StressXpress - SKT-211Chemical Structure of Cyclic GMP for the Cyclic GMP EIA Kit StressXpress - SKT-211
Product Name Cyclic GMP EIA Kit (Discontinued)
Description

Quantitative colorimetric detection of cGMP

Species Reactivity Species Independent
Platform Microplate
Sample Types Cell lysates, EDTA Plasma, Saliva, Tissue, Tissue Culture Media, Urine
Detection Method Colorimetric Assay
Assay Type Direct EIA (Enzyme Immunoassay)
Utility EIA kit used to quantitatively measure cGMP present in samples.
Sensitivity 0.28 pmol/ml
Assay Range Regular: 0.5 - 32 pmol/ml. Acetylated: 0.3125 - 20 pmol/ml
Precision Intra Assay Precision (Regular): Three human urine samples were diluted with Sample Diluent and run in replicates of 20 in an assay. The mean and precision of the calculated cGMP concentrations were: Sample 1- 8.5 pmol/mL, 6.3% CV Sample 2- 4.0 pmol/mL, 7.8% CV Sample 3- 1.2 pmol/mL, 13.6% CV Intra Assay Precision (Acetylated): Three human urine samples were diluted with Sample Diluent, acetylated and run in replicates of 20 in an assay. The mean and precision of the calculated cGMP concentrations were: Sample 1- 8.1 pmol/mL, 3.8% CV Sample 2- 3.8 pmol/mL, 5.2% CV Sample 3- 1.2 pmol/mL, 8.2% CV Inter Assay Precision (Regular): Three human urine samples were diluted with Sample Diluent and run in duplicates in twelve assays run over multiple days by three operators. The mean and precision of the calculated cGMP concentrations were: Sample 1- 8.5 pmol/mL, 6.5% CV Sample 2- 4.3 pmol/mL, 7.0% CV Sample 3- 1.5pmol/mL, 8.3% CV Inter Assay Precision (Acetylated): Three human urine sample weres diluted with Sample Diluent, acetylated and run in duplicates in twelve assays run over multiple days by three operators. The mean and precision of the calculated cGMP concentrations were: Sample 1- 8.7 pmol/mL, 12.3% CV Sample 2- 4.3 pmol/mL, 14.3% CV Sample 3- 1.5 pmol/mL, 14.2% CV
Number of Samples 39 samples in duplicate
Other Resources Kit Booklet , MSDS , Saliva Sample Handling Instructions
Field of Use Not for use in humans. Not for use in diagnostics or therapeutics. For in vitro research use only.

Properties

Storage Temperature 4ºC
Shipping Temperature Blue Ice
Product Type EIA Kits
Assay Overview The Cyclic GMP (cGMP) EIA kit is designed to quantitatively measure cGMP present in lysed cells, EDTA plasma, urine, saliva and tissue culture media samples. For samples where the levels of cGMP are expected to be relatively high, the regular format for the assay can be used. For samples with expected low levels of cGMP, an optional acetylation protocol can be used. The kit is unique in that all samples and standards are diluted into an acidic Sample Diluent, which contains special additives and stabilizers, for cGMP measurement. This allows plasma, urine and saliva samples to be read in an identical manner to lysed cells. Acidified samples of cGMP are stable and endogenous phosphodiesterases are inactivated in the Sample Diluent. A cGMP standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. A clear microtiter plate coated with an antibody to capture mouse IgG is provided and a neutralizing Plate Primer solution is added to all the used wells. Standards or diluted samples, either with or without acetylation, are pipetted into the primed wells. A cGMP-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a mouse monoclonal antibody to cGMP to each well. After a 2 hour incubation, the plate is washed and substrate is added. The substrate reacts with the bound cGMP-peroxidase conjugate. After a short incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450 nm wavelength. The concentration of the cGMP in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers.
Kit Overview
Component No.ItemQuantity / Size
SKC-211A Coated Clear 96 Well Plates 1 Each
SKC-211B Cyclic GMP Standard 70 µl
SKC-211C StressXpress® Cyclic GMP Antibody 3 ml
SKC-211D StressXpress® Cyclic GMP Conjugate 3 ml
SKC-211E Sample Diluent 28 ml
SKC-211F Plate Primer 5 ml
SKC-211G Acetic Anhydride 2 ml
SKC-211H Triethylamine 4 ml
SKC-211I Wash Buffer Concentrate 30 ml
SKC-211J TMB Substrate 11 ml
SKC-211K Stop Solution 5 ml
SKC-211L Plate Sealer 1 Each
Cite This Product Cyclic GMP EIA Kit (StressMarq Biosciences Inc., Victoria BC CANADA, Catalog # SKT-211)

Biological Description

Alternative Names cGMP; 3',5'-cyclic GMP EIA Kit, Guanosine cyclic monophosphate EIA Kit, Cyclic 3',5'-GMP; Guanosine 3',5'-cyclic phosphate EIA Kit
Research Areas Cell Signaling, Neuroscience
Scientific Background Guanosine 3’, 5’-cyclic monophosphate (cyclic GMP; cGMP) is a critical and multifunctional second messenger present at levels typically 10-100 fold lower than cAMP in most tissues. Intracellular cGMP is formed by the action of the enzyme guanylate cyclase on GTP and degraded through phosphodiesterase hydrolysis (1-3). Guanylate cyclases (GC) are either soluble or membrane bound (3,4). Soluble GCs are nitric oxide responsive, whereas membrane bound GCs respond to hormones such as acetylcholine, insulin and oxytocin. Other chemicals like serotonin and histamine also cause an increase in cGMP levels (5,6). Cyclic GMP regulates cellular composition through cGMP-dependent kinase, cGMP-dependent ion channels or transporters, and through its hydrolytic degradation
by phosphodiesterase (1,7)
References 1. Domek-Lopacinska, K. and Strosznajder, JB. (2005) J Physiol Pharmacol 56 Suppl 2, 15-34.
2. Lucas, K.A. et al. (2000) Pharmacol Rev 52: 375-414.
3. Ashman, DF., et al. (1963) , Biochem Biophys Res Comm, 11: 330-4.
4. Potter LR, Abbey-Hosch S, and Dickey DM. (2006) Endocr Rev 27: 47-72.
5. Waldman, SA and Murad, F. (1987) Pharmacol Revs, 39: 163-197.
6. Tremblay J, Gerzer R, and Hamet P. (1988) , Adv. 2nd Messanger & Phosphoprotein Res., 22: 319-383.
7. Matsumoto T, Kobayashi T, and Kamata K. (2003) J Smooth Muscle Res 39: 67-86.

Product Images

<p>Regular Format Typical Standard Curve for the Cyclic GMP EIA Kit (Enzyme Immunoassay) StressXpress® – SKT-211. Assay Type: Direct EIA. Detection Method: Colorimetric Assay. Assay Range: Regular: 0.5 – 32 pmol/ml. Acetylated: 0.3125 – 20 pmol/ml.</p>

Regular Format Typical Standard Curve for the Cyclic GMP EIA Kit (Enzyme Immunoassay) StressXpress® – SKT-211. Assay Type: Direct EIA. Detection Method: Colorimetric Assay. Assay Range: Regular: 0.5 – 32 pmol/ml. Acetylated: 0.3125 – 20 pmol/ml.

<p>Acetylated Format Typical Standard Curve for the Cyclic GMP EIA Kit (Enzyme Immunoassay) StressXpress® – SKT-211. Assay Type: Direct EIA. Detection Method: Colorimetric Assay. Assay Range: Regular: 0.5 – 32 pmol/ml. Acetylated: 0.3125 – 20 pmol/ml.</p>

Acetylated Format Typical Standard Curve for the Cyclic GMP EIA Kit (Enzyme Immunoassay) StressXpress® – SKT-211. Assay Type: Direct EIA. Detection Method: Colorimetric Assay. Assay Range: Regular: 0.5 – 32 pmol/ml. Acetylated: 0.3125 – 20 pmol/ml.

<p>Linearity was determined by taking two human urine samples, one with a low cGMP level of 0.3 pmol/mL and one with a higher level of 9.7 pmol/mL, and mixing them in ratios. The measured concentrations were compared to the expected values based on the ratios used.</p>

Linearity was determined by taking two human urine samples, one with a low cGMP level of 0.3 pmol/mL and one with a higher level of 9.7 pmol/mL, and mixing them in ratios. The measured concentrations were compared to the expected values based on the ratios used.

<p>Chemical structure of cGMP (3′,5′-cyclic GMP)</p>

Chemical structure of cGMP (3′,5′-cyclic GMP)

Reviews

Reviews

There are no reviews yet.

Be the first to review “Cyclic GMP EIA Kit (Discontinued)”

Your email address will not be published. Required fields are marked *