StressXpress®
Glutathione Detection Kit (Discontinued)

Fluorescent detection of total GSH content

Catalog No. SKT-202

0 out of 5 based on 0 customer ratings
Species Reactivity ALL
Sample Types Cell lysates, EDTA Plasma, Erythrocytes, Heparin Plasma, Serum, Tissue, Urine, Whole Blood
SKU: SKT-202 Categories: ,

Clear
SKT-202_Glutathione_Detection_Kit_Standard_Curve_Fig1.png
Graph of the Linearity Recovery for the Glutathione Detection Kit StressXpress - SKT-202Graph of the Kit Correlation Data for the Glutathione Detection Kit StressXpress - SKT-202
Product Name Glutathione Detection Kit (Discontinued)
Description

Fluorescent detection of total GSH content

Species Reactivity Species Independent
Platform Microplate
Sample Types Cell lysates, EDTA Plasma, Erythrocytes, Heparin Plasma, Serum, Tissue, Urine, Whole Blood
Detection Method Fluorometric Assay
Assay Type Direct Quantitative Assay
Utility Fluorometric detection assay to measure the total GSH content in samples.
Sensitivity 45 nM in the Free GSH and 48 nM in the Total GSH
Assay Range 0.195 - 25 uM
Precision Intra Assay Precision:Two each of SSA treated human urine and whole blood samples were further diluted in 1% SSA Sample Diluent and run in replicates of 20 in an assay. The mean and precision of the calculated GSH concentrations were: Sample 1 (Free)- 1.27 µM, 4.0% CV, Sample 1 (Total)- 2.30 µM, 4.7% CV Sample 2 (Free)- 2.00 µM, 3.1% CV, Sample 2 (Total)- 3.80 µM, 4.7% CV Sample 3 (Free)- 8.33 µM, 4.6% CV, Sample 3 (Total)- 9.77 µM, 2.7% CV Sample 4 (Free)- 3.89 µM, 3.0% CV, Sample 4 (Total)- 4.45 µM, 2.3% CV Inter Assay Precision: Two each of SSA treated human urine and blood samples were further diluted in 1% SSA Sample Diluent and run in duplicates in twenty assays run over multiple days by two operators. The mean and precision of the calculated GSH concentrations were: Sample 1 (Free)- 1.30 µM, 8.6% CV, Sample 1 (Total)- 2.40 µM, 9.3% CV Sample 2 (Free)- 1.83 µM, 14.7% CV, Sample 2 (Total)- 3.57 µM, 10.0% CV Sample 3 (Free)- 9.38 µM, 6.0% CV, Sample 3 (Total)-11.67 µM, 6.0% CV Sample 4 (Free)- 4.89 µM, 7.2% CV, Sample 4 (Total)- 5.89 µM, 8.0% CV
Number of Samples 39 samples in duplicate
Other Resources Kit Booklet , MSDS
Field of Use Not for use in humans. Not for use in diagnostics or therapeutics. For in vitro research use only.

Properties

Storage Temperature 4ºC
Shipping Temperature Blue Ice
Product Type Detection Kits
Assay Overview The Glutathione Fluorescent Detection kit is designed to quantitatively measure glutathione (GSH), and oxidized glutathione (GSSG) present in a variety of samples. The kit is unique in that both free and oxidized glutathione are detected in the same well in the microtiter plate. No separation or washing is required. Total glutathione is the sum of GSSG plus GSH. A GSH standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. The kit utilizes a proprietary non-fluorescent molecule, StressXpress® Detection Reagent, that will covalently bind to the free thiol group on GSH to yield a highly fluorescent product. After mixing the sample or standard with the Detection Reagent and incubating at room temperature for 15 minutes, the fluorescent product is read at 510 nm in a fluorescent plate reader with excitation at 390 nm. The concentration of the GSH in the sample is calculated, after making a suitable correction for any dilution of the sample, using software available with most fluorescence plate readers. Free glutathione, GSH, is read first after 15 minutes, followed by addition of a reaction mixture that converts all the oxidized glutathione, GSSG, into free GSH, which then reacts with the excess Detection Reagent to yield the signal related to Total GSH content. The total concentration of GSH generated in the sample is calculated from the generated signal. We have provided a 96 well plate for measurement but this assay is adaptable for higher density plate formats. The end user should ensure that their HTS black plate is suitable for use with these reagents prior to running samples.
Kit Overview
Component No.ItemQuantity / Size
SKC-202A Black 96 Well Plate 1 Each
SKC-202B Glutathione Standard 100 µl
SKC-202C StressXpress® Detection Reagent 2 Platic Vials
SKC-202D Dry DMSO 4 ml
SKC-202E Assay Buffer 60 ml
SKC-202F NADPH Concentrate 300 µl
SKC-202G Glutathione Reductase Concentrate 300 µl
SKC-202H Oxidized Glutathione Control 300 µl
Cite This Product Glutathione Detection Kit (StressMarq Biosciences Inc., Victoria BC CANADA, Catalog # SKT-202)

Biological Description

Alternative Names γ-L-Glutamyl-L-cysteinylglycine Detection Kit (2S)-2-Amino-5-[[(2R)-1-(carboxymethylamino)-1-oxo- 3-sulfanylpropan-2-yl]amino]-5-oxopentanoic acid Detection Kit
Research Areas Cancer, Oxidative Stress
Scientific Background Glutathione (L-γ-glutamyl-L-cysteinylglycine; GSH) is the highest concentration non-protein thiol in mammalian cells and is present in concentrations of 0.5 - 10 mM (1). GSH plays a key role in many biological processes, including the synthesis of proteins and DNA, the transport of amino acids, and the protection of cells against oxidation. Harmful hydrogen peroxide cellular levels are minimized by the enzyme glutathione peroxidase (GP) using GSH as a reductant (2). The oxidized GSH dimer, GSSG, is formed from GSH and peroxide by the GP reaction (see below). An important role of GSSG in the NFγB activating signal cascade is suggested by the facts that the potent NFγB inducer, tetradecanoyl phorbol acetate, increases intracellular GSSG levels and GSSG/GSH ratios (3). Glutathione S-transferases (GST) are an important group of enzymes that catalyze the nucleophilic addition of GSH to electrophiles. They are encoded by 5 gene families; 4 encode cytosolic GST and one encodes the microsomal form of GST. They have been implicated in a number of diseases. In asthma arachidonic acid is converted to unstable leukotriene A4 (LTA4). LTA4 is either hydrated to form LTB4 or it is conjugated to GSH by a GST, leukotriene C4 synthase, to form leukotriene C4. LTC4 and its derivative LTD4 are important molecules in bronchial asthma. Leukotriene C4 synthase is therefore an important therapeutic target. It has also been shown that increased expression of GSTs can lead to drug resistance. Three glutathione adducts of the drug melphalan, used to treat ovarian cancer and multiple myeloma, have been isolated from reactions involving human microsomal GSTs.
References 1. Meister A. (1988) Trends Biochem Sci. 13(5): 185-8.
2. Meister A. (1994) J Biol Chem. 269(13): 9397-400.
3. Dröge W., et al. (1994) FASEB J. 8(14): 1131-8.

Product Images

<p>Typical Standard Curve of Glutathione Detection Kit StressXpress® – SKT-202. Assay Type: Direct. Detection Method: Fluorometric Assay. Assay Range: 0.195 – 25 uM</p>

Typical Standard Curve of Glutathione Detection Kit StressXpress® – SKT-202. Assay Type: Direct. Detection Method: Fluorometric Assay. Assay Range: 0.195 – 25 uM

<p>Linearity was determined by taking human RBCs at two different concentrations and mixed in the ratios given below. The measured concentrations were compared to the expected values based on the ratios used.</p>

Linearity was determined by taking human RBCs at two different concentrations and mixed in the ratios given below. The measured concentrations were compared to the expected values based on the ratios used.

<p>We purchased and compared a popular colorimetric total glutathione assay kit (kit “T”) that uses Ellman’s reagent to detect free glutathione in the sample. Initial experiments used random human urine samples that were processed as described in each kit booklet. With kit “T”, the values obtained for urine after the recommended treatment with 4 volumes of 5% metaphosphoric acid and subsequent 10 fold dilution with assay buffer put all the values well below the lowest standard. However, the urine samples run in the StressXpress® kit gave Total GSH values between 0.63 and 4.04 ?M.</p>

We purchased and compared a popular colorimetric total glutathione assay kit (kit “T”) that uses Ellman’s reagent to detect free glutathione in the sample. Initial experiments used random human urine samples that were processed as described in each kit booklet. With kit “T”, the values obtained for urine after the recommended treatment with 4 volumes of 5% metaphosphoric acid and subsequent 10 fold dilution with assay buffer put all the values well below the lowest standard. However, the urine samples run in the StressXpress® kit gave Total GSH values between 0.63 and 4.04 ?M.

Reviews

Reviews

There are no reviews yet.

Be the first to review “Glutathione Detection Kit (Discontinued)”

Your email address will not be published. Required fields are marked *