Glutathione S-Transferase Activity Kit (Discontinued)

Quantitative fluorometric measurement of the activity of GST

Catalog No. SKT-203

0 out of 5 based on 0 customer ratings
Species Reactivity Hu, Mlsk, Fs
Sample Types Cell lysates, EDTA Plasma, Heparin Plasma, Serum, Urine
SKU: SKT-203 Categories: ,

SKT-203_Glutathione_S-Transferase_Activity_Kit_Continuous_Kinetic_Assay_Standard_Curve_Fig3.png
Graph of the End-Point Assay Typical Standard Curve for the Glutathione S-Transferase Activity Kit StressXpress - SKT-203Graph of the Linearity Recovery for the Glutathione S-Transferase Activity Kit StressXpress - SKT-203
Product Name Glutathione S-Transferase Activity Kit (Discontinued)
Description

Quantitative fluorometric measurement of the activity of GST

Platform Microplate
Sample Types Cell lysates, EDTA Plasma, Heparin Plasma, Serum, Urine
Detection Method Fluorometric Assay
Assay Type Direct Enzyme Activity Assay
Utility Fluorometric assay used to quantitatively measure the activity of glutathione S-transferase in samples.
Precision Intra Assay Precision:Four serum samples were diluted 1:2 with Assay Buffer and run in replicates of 16 in an assay. The mean and precision of the calculated GST activities were: Sample 1- 315.9 mU/mL, 4.6% CV Sample 2- 221.2 mU/mL, 5.6% CV Sample 3- 88.2 mU/mL, 4.2% CV Sample 4- 22.7 mU/mL, 6.6% CV Inter Assay Precision: Four serum samples were diluted 1:2 with Assay Buffer and run in duplicates in twenty assays over multiple days by four operators. The mean and precision of the calculated GST activities were: Sample 1- 291.7 mU/mL, 12.6% CV Sample 2- 218.5 mU/mL, 11.0% CV Sample 3- 89.6 mU/mL, 10.4% CV Sample 4- 23.0 mU/mL, 15.9% CV
Incubation Time 30 minutes
Number of Samples 40 samples in duplicate
Other Resources Kit Booklet , MSDS
Field of Use Not for use in humans. Not for use in diagnostics or therapeutics. For in vitro research use only.

Properties

Storage Temperature 4ºC
Shipping Temperature Blue Ice
Product Type Activity Kits
Assay Overview The Glutathione S-Transferase Activity kit is designed to quantitatively measure the activity of GST present in a variety of samples. A GST standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. The kit utilizes a non-fluorescent molecule that is a substrate for the GST enzyme which covalently attaches to glutathione (GSH) to yield a highly fluorescent product. Mixing the sample or standard with the supplied Detection Reagent and GSH and incubating at room temperature for 30 minutes yields a fluorescent product which is read at 460 nm in a fluorescent plate reader with excitation at 390 nm. The activity of the GST in the sample is calculated, after making a suitable correction for any dilution of the sample, using software available with most fluorescence plate readers. We have provided a 96 well plate for measurement but this assay is adaptable for higher density plate formats. The end user should ensure that their HTS black plate is suitable for use with these reagents prior to running samples.
Kit Overview
Component No.ItemQuantity / Size
SKC-203A Black Half Area 96 Well Plate 1 Plate
SKC-203B Glutathione S-Transferase Standard 50 µl
SKC-203C GST Detection Reagent 1 vial
SKC-203D Dry DMSO 2 ml
SKC-203E Assay Buffer 45 ml
SKC-203F Glutathione (GSH) 300 µl
Cite This Product Glutathione S-Transferase Activity Kit (StressMarq Biosciences Inc., Victoria BC CANADA, Catalog # SKT-203)

Biological Description

Alternative Names γ-L-Glutamyl-L-cysteinylglycine Activity Kit (2S)-2-Amino-5-[[(2R)-1-(carboxymethylamino)-1-oxo- 3-sulfanylpropan-2-yl]amino]-5-oxopentanoic acid Activity Kit
Research Areas Cancer, Oxidative Stress
Scientific Background The Glutathione S-Transferase (GST) family of isozymes function to detoxify and neutralize a wide variety of electrophilic molecules by mediating their conjugation with reduced glutathione (1). Human GSTs are encoded by 5 gene families, expressing in almost all tissues as four cytosolic and one microsomal forms. Dividing the family by isoelectric points, the basic alpha (pI 8–11), the neutral mu (pI 5–7) and acidic pi (pH<5) classes are populated by additional subclasses, each isozyme displaying differential specificity for given electrophilic molecules (2).
Given its pivotal role in ameliorating oxidative stress/damage, GST activity has been repeatedly investigated as a biomarker for arthritis, asthma, COPD, and multiple forms of cancer, as well as an environmental marker (3-7). Examination of GST isoforms and activity in human cancers, tumors and tumor cell lines has revealed the predominance of the acidic pi class. Furthermore, this activity is thought to substantially contribute to the innate or acquired resistance of specific neoplasms to anticancer therapy (8,9).
References 1. Habig, W, et al. J. Biol.Chem. 1974 249(22):7130-7139.
2. Cook, JA, et al. Cancer Res. 1991 51:1606-1612.
3. Dalle-Donne, I, et al. 2006 52(4):601-623.
4. Surapneni, KM & VSC Gopan. Ind.J.Clin.Biochem. 2008 23(1):41.44.
5. Mohan, SK & O Venkataramana. Ind.J.Med. Sci. 2007 61:9-14.
6. Ferrandina, G., et al. Ann. Oncol. 1997 8:343-350.
7. Otitoju, O & Onwarah, INE. African J. Biotech. 2007 6(12)1455-1459.
8. Shea, TC, et al. Cancer Res. 1988 48:527-533.
9. Shea, TC, et al. Cancer Res. 1990 50:6848-6853.

Product Images

<p>Continuous Kinetic Assay Typical Standard Curve for Glutathione S-Transferase Activity Kit (Enzyme Activity Assay) StressXpress® – SKT-203. Assay Type: Direct. Detection Method: Fluorometric Assay. Assay Range: 7.81 – 500 mU/ml.</p>

Continuous Kinetic Assay Typical Standard Curve for Glutathione S-Transferase Activity Kit (Enzyme Activity Assay) StressXpress® – SKT-203. Assay Type: Direct. Detection Method: Fluorometric Assay. Assay Range: 7.81 – 500 mU/ml.

<p>End-Point Assay Typical Standard Curve for Glutathione S-Transferase Activity Kit (Enzyme Activity Assay) StressXpress® – SKT-203. Assay Type: Direct. Detection Method: Fluorometric Assay. Assay Range: 7.81 – 500 mU/ml.</p>

End-Point Assay Typical Standard Curve for Glutathione S-Transferase Activity Kit (Enzyme Activity Assay) StressXpress® – SKT-203. Assay Type: Direct. Detection Method: Fluorometric Assay. Assay Range: 7.81 – 500 mU/ml.

<p>Linearity was determined by taking Jurkat cell lysates at 10 x 106 and 0.8 x 106 cells/mL and mixing in the ratios given below. The measured activities were compared to the expected values based on the ratios used.</p>

Linearity was determined by taking Jurkat cell lysates at 10 x 106 and 0.8 x 106 cells/mL and mixing in the ratios given below. The measured activities were compared to the expected values based on the ratios used.

Reviews

Reviews

There are no reviews yet.

Be the first to review “Glutathione S-Transferase Activity Kit (Discontinued)”

Your email address will not be published. Required fields are marked *